Hematology Analyzer

Hematology Analyzer
Product Detailed
Automatic 3-diff on WBC Touch screen 70 tests per hour Double counting cells Built-in dilution device

MTN-31 Automatic Hematology Analyzer

1.Function: Automatic WBC 3 part, 23 parameters (including WBC, RBC, PLT color histograms)

2,Principle: Electrical impedance method for counting and cyanide-free colorimetric method for hemoglobin

3,Test items: WBC, LYM#,MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, and WBC, RBC, PLT histograms

4. Throughput:≥70 samples/hour(<55 second/test), 24h power on, with dormancy and wake function

5,Sample type: venous blood, peripheral blood, diluted peripheral blood

6,Sample volume: venous blood ≤9.6ul, peripheral blood ≤9.6ul, diluted peripheral blood ≤20ul, allow for secondary testing

7,Work mode: Double counting cell, automated sampling and measuring. Built-in dilution device, automatic join hemolysin to the host, and automated dilute second time.

8,Blockage Removal system: soak, positive & negative washing, real-time monitoring high pressure scorching etc multiple intelligence exhausting, with the Monitoring function for incomplete plugging hole.

9,Alarm: automated system diagnose, self-check function, error warning and prompt functions, including insufficient reagent alarm.

10. Autonomous Maintenance: Instrument with the fuction of autonomous maintenance, soaking the pipeline to reduce the plugging.

11,Large storage capability: 100000 samples’ parameters and three histograms

12,Calibration: Three test modes offer independent automated calibration and manual calibration, special calibration solution provided

13,LCD: Touch screen

Performance index

 

Repeatability error

Linear range

WBC

<2.0%

0.0-99.9x109/L

RBC

<1.5%

0.0-99.9x1012/L

HGB

<1.5%

0-300g/L

MCV

<0.4%

40-150Fl

HCT

<1.0%

0.0-100.0%

PLT

<4.0%

0-99.9x109/L

 

Cross infection rates: RBC, WBC, HGB<0.5%,PLT<1.0%

Work environment: 220(1±10%)V, (50±1)Hz, temperature 10°C-35°C, humidity10%-90%.